18.12.2020»»пятница

Siemens Starter 4.5 Download

18.12.2020
  1. Siemens Starter 4.5 Download Install
  2. Siemens Starter Software 4.5 Download
  3. Siemens Starter 4.5 Download Offline
Product Catalogue

Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. 3RA22101GA152BB4 from Siemens at Allied Electronics & Automation. Raspberry Pi, Arduino & Development Tools. Irctc Connect Windows App Download Siemens Starter 4.5 Download All Mp4 Movies Free Download Jilla Tamil Movie Download Star Plus All Serials Registry Mechanic Download Deep Freeze Software Phone Unlocker Software Idt Audio Codec Download Windows 10.

Siemens
  • Product Catalogue
  • eClass 5.1
  • eClass 6
  • eClass 9
  • eClass 9.1

SINAMICS G120 software V4.5 incl. SSP for STARTER SIEMENS SINAMICS G120 software V4.5 incl. SSP for STARTER ARTSPlusRQ Brief description Circumstances Possible work-around Affected DO Since version SINAMICSSW - General AP00921575 Acknowledgment of faults using the 'OK button in the menu 'DIAGNOSTICS/FAULTS' at the BOP-2 does not result in the. 4 5 Power Module The device is available in several sizes and degrees of protection. It has a power range extending from 0.37 kW up to 90 kW (75 kW for IP20). The power modules are available in both IP20 and IP55. IP20 IP55 Please check the rating plate to make sure that the power module also meets your require-ment specifications. STARTER V4.5.1.3 is an application marketed by the software company Siemens AG. Sometimes, users choose to uninstall this program. This can be difficult because deleting this by hand requires some advanced knowledge related to Windows internal functioning.

3RV2111-1FA10
Circuit breaker size S00 for motor protection, CLASS 10 with overload relay function A-release 3.5..5 A N release 65 A screw terminal Standard switching capacity
List Price Show prices
Customer PriceShow prices
DataSheet in PDF Download
Service & Support (Manuals, Certificates, FAQs..) Download
0'>
0'>
Customer Price
Loading
Product
Article Number (Market Facing Number)3RV2111-1FA10
Product Description Circuit breaker size S00 for motor protection, CLASS 10 with overload relay function A-release 3.5..5 A N release 65 A screw terminal Standard switching capacity
Product familySIRIUS 3RV2 motor starter protectors
Product Lifecycle (PLM)PM300:Active Product
Price data
Price Group
List PriceShow prices
Customer PriceShow prices
Surcharge for Raw MaterialsNone
Metal FactorLAP-----
Delivery information
Export Control RegulationsAL : N / ECCN : N
Standard lead time ex-works2 Day/Days
Net Weight (kg)0,411 Kg
Product Dimensions (W x L x H)Not available
Packaging Dimension72,50 x 108,00 x 104,50
Package size unit of measureMM
Quantity Unit1 Piece
Packaging Quantity1
Additional Product Information
EAN4011209713376
UPC662643923094
Commodity Code85362090
LKZ_FDB/ CatalogIDCC-IC10
Product Group5332
Group CodeR711
Country of originGermany
Compliance with the substance restrictions according to RoHS directiveSince: 01.10.2009
Product classA: Standard product which is a stock item could be returned within the returns guidelines/period.
WEEE (2012/19/EU) Take-Back ObligationYes
REACH Art. 33 Duty to inform according to the current list of candidates

Information obligation imposed by Article 33, REACH Regulation: This product includes one or several articles in which the following substance of the candidate list is contained in concentrations higher than 0,1% weight by weight (w/w):

Lead

Based on the information currently available, we assume that these substances do not pose any risk if the articles are used as intended (including disposal). Please also refer to product documentation.

Classifications
Version Classification
eClass627-37-04-01
eClass7.127-37-04-01
eClass827-37-04-01
eClass927-37-04-01
eClass9.127-37-04-01
ETIM4EC000074
ETIM5EC000074
ETIM6EC000074
ETIM7EC000074
IDEA44845
UNSPSC1439-12-15-21
UNSPSC1539-12-16-01

DESCRIPTION
This contains the last two STARTER versions and additive SINAMICS Support Packages:

SINAMICS MICROMASTER STARTER V4.3 SP3 (latest version)

SINAMICS MICROMASTER STARTER V4.3 SP3
(Release for general availability: 2013-08-09)

Associated sales information Item ID: 78817896

Description

Vol_1_STARTER_V43_SP3_Program.zip ( 684174 KB ) 1)

Vol_2a_STARTER_V43_SP3_SSPs_G110_G120.zip1 ( 393861 KB ) 1)

optionally:

Vol_2b_STARTER_V43_SP3_SSPs_Rest_of_SINAMICS_Family.zip ( 487983 KB ) 1)

optionally:

Vol_3_STARTER_V43_SP3_HELPS.zip ( 856992 KB ) 1)

Hotfix 1 for SINAMICS MICROMASTER STARTER V4.3 SP3 (Release for general availability: 09.08.2013)

Associated sales information Item ID: 78817896. With the Hotfix 1 for STARTER V4.3 SP3, the following restriction is eliminated: Restriction regarding the STARTER trace function with SINAMICS G120 drives and a drive firmware version that is lower than Version V4.6. Also see description.

Description

SINAMICS_MICROMASTER_STARTER_V04_03_03_01.zip ( 11528 KB )

1) Please take note of download instructions!

SINAMICS MICROMASTER STARTER V4.3 SP2 (previous version)

SINAMICS MICROMASTER STARTER V4.3 SP2
(Release for general availability: 2013-02-28)

Associated sales information Item ID: 64374921

Description

Vol_1_STARTER_V43_SP2_Program.zip ( 684917 KB ) 1)

Vol_2a_STARTER_V43_SP2_SSPs_G110_G120.zip ( 314543 KB ) 1)

optionally:

Vol_2b_STARTER_V43_SP2_SSPs_Family_Integrated.zip ( 422511 KB ) 1)

optionally:

Vol_3_STARTER_V43_SP2_HELPS.zip ( 878893 KB ) 1)

1) Please take note of download instructions!

SSPs for updating existing STARTER V4.3.2.x resp. SCOUT V4.3.1.x installations (please read detailed description)
STARTER
V4.3.1.x
SCOUT
V4.3.1.x
(X>=12)
STARTER
V4.3.2.x
SSP, SINAMICS V4.6

SSP_SINAMICS_V4_6.zip ( 26863 KB ) 1)

XXX
SSP, SINAMICS G120 CU250S VECTOR V4.6

SSP_SINAMICS_CU250S_VEC_V46.zip ( 25776 KB ) 1)

--X
SSP, SINAMICS DCM V1.4

SSP_SINAMICS_DCM_V1_4.zip ( 65385 KB ) 1)

--X
SSP, SINAMICS G120 V4.6

SSP_SINAMICS_G120_V4_6.zip ( 132835 KB ) 1)

XXX
SSP, SINAMICS MV V4.6

SSP_SINAMICS_MV_V4_6.zip ( 22284 KB ) 1)

XXX
Online Helps STARTER for Version V4.6

optional:

Vol_3_STARTER_V43_SP3_HELPS.zip ( 856992 KB ) 1)

XXX
1) Please take note of download instructions!

Hotfix 1 for SINAMICS MICROMASTER STARTER V4.3 SP3

Here you can find the Hotfix 1 for the Version V4.3 SP3 for the STARTER commissioning tool for the drive systems SINAMICS und MICROMASTER 4.

Siemens Starter 4.5 Download Install

The Hotfix 1 setup is provided as a ZIP file (approx. 11.26 MB) and does not comprise a full STARTER version, but only the files which are used to correct the stated functional restriction.
Therefore, the Hotfix 1 can only be installed additionally to an already installed STARTER V4.3 SP3. The affected files are replaced during the setup.

Procedure:
Download the ZIP file and unpack it into an arbitrary directory. Then start the installation with /CD_1/Setup.exe.
The Readme file under /01_Readme contains important notes on how to use the HotFix setup.

In the Hotfix 1 for the STARTER V4.3 SP3, the following restrictions has been corrected:

  • Restriction regarding the STARTER trace function with SINAMICS G120 drives and a drive firmware version that is lower than Version V4.6
    If the trace function is started on a SINAMICS G120 Control Unit with Starter V4.3 SP3, an error message is output. The trace function cannot be started with the STARTER. This STARTER behavior occurs on G120 Control Units with a firmware version lower than Version V4.6.x (e.g. V4.5.x, V4.4.x).

More detailed information regarding general and new functions of the STARTER Version V4.3 SP3 is provided in the article ID: 78817896.

SINAMICS MICROMASTER STARTER V4.3 SP3

This contains version V4.3 SP3 of the STARTER commissioning tool for the SINAMICS, SIMATIC ET200 FC and MICROMASTER 4 drive systems. The download also contains the additive SINAMICS Support Packages in the file 'Vol_2a_STARTER_V43_SP3_ SSPs_G110_G120.zip' and 'Vol_2b_STARTER_V43_SP3_ SSPs_Family_Integrated':

  • Support of the
    • G120 CU250S-2 Vector with Firmware V4.6
    • G120P with Firmware V4.6 (SSP G120)
    • G120P BT with Firmware V4.6
    • DCM with Firmware V1.4
  • Support of the new firmware versions for
    • MICROMASTER 4th Generation
    • SIMATIC ET200pro FC and
    • SINAMICS G110/G110D

    as stated more below in the text for each installation of the STARTER program package (no SSPs).

These SSPs are automatically installed by the STARTER setup when the checkboxes are activated in the selection screen form.

SINAMICS MICROMASTER STARTER can be used free of charge without entering a license key. However, for legal licensing reasons, you should be in possession of a STARTER license certificate (any version). If this is not the case, you can also order the current STARTER version including license certificate on a DVD. Order number: 6SL3072-0AA00-0AG0.

STARTER V4.3 SP2 supports German, English, French, Spanish and Italian.

The following drive systems are supported
(recently included versions compared to the previous STARTER V4.3.3 are marked in bold):

  • MICROMASTER 4th Generation (MM420 V1.30, MM440 V2.20, MM430 V2.20)
  • SINAMICS DCM with Firmware V1.1, V1.2, V1.3 and (with SSP) V1.4
  • SIMATIC ET200S FC with Firmware V1.0.x, V3.0.x
  • SIMATIC ET200pro FC with Firmware V3.0.x, V3.1.x
  • SINAMICS G110 with Firmware V1.0.x, V1.1.x, 1.2.x
  • SINAMICS G110D with Firmware V3.3.x, V3.4.x, V3.6.x
  • SINAMICS G120 with Firmware V2.0.x, V2.1.x, V3.0.x, V3.1.x, V3.2.x
  • SINAMICS G120 with Firmware V4.2, V4.3.0, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G120C with Firmware V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G120D with Firmware V3.0.x, V3.1.x, V3.2.x, V4.5 and (with SSP) V4.6
  • SINAMICS G120P with Firmware V4.2, V4.3.0, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G120P BT with Firmware V4.4.1 and (with SSP) V4.6
  • SINAMICS G130 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS G130 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G150 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS G150 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS GM150 with Firmware V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS GL150 with Firmware V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS GL150 with Firmware V4.3.1, V4.4.2, V4.5 (--> SINAMICS MV)
  • SINAMICS S110 with Firmware V4.1, V4.3.1, V4.3.2, V4.4
  • SINAMICS S120 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS S120 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS S150 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS S150 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS SL150 with Firmware V4.3.1, V4.4.2, V4.5 (--> SINAMICS MV)
  • SINAMICS SM120 with Firmware V4.4.2 (--> SINAMICS MV)
  • SINAMICS MV (GM150/GL150/SL150/SM120) with Firmware V4.6

Further details on the supported drive systems can be found in the following Excel overview.

  • German
    Installierte_Geraete_STARTER_DVD_43030000.pdf ( 22 KB )
  • English
    Installed_Devices_STARTER_DVD_43030000.pdf ( 22 KB )

Optional, NEW
In order to save download time and data volume, this STARTER version V4.3 SP3 can also be downloaded and installed WITHOUT online help and WITHOUT SINAMICS S/SINAMICS integrated drives. If you do not want to use the online help, then select the 'Minimized' download version.

Installation/download version

Complete,
i.e. download
all SINAMICS drives
files including online help

SINAMICS partial range,
i.e. only download MICROMASTER 4 and SINAMICS G110 and G120
including online help

SINAMICS partial range and minimized,
i.e. only download MICROMASTER 4 and SINAMICS G110 and G120
WITHOUT online help

Vol_1_STARTER_V43_SP3_Program.zip

YES

YES

YES

Vol_2a_STARTER_V43_SP3_SSPs_G110_G120.zip

YES

YES

YES

Vol_2b_STARTER_V43_SP3_SSPs_Family_Integrated.zip

YES

NO

NO

Vol_3_STARTER_V43_SP3_Helps.zip

YES

YES

NO

Procedure to install STARTER V4.3 SP3:

  1. Download the 2 or 3 or 4 attached ZIP files (depending on the selected download version)
  2. Unpack the ZIP files into a shared target directory on your hard disk. Please ensure that there are no spaces in the entire path name of this target directory.
  3. After unpacking, the shared directory must appear as follows (shown for the 'complete' version):
    ..SharedDirectory01_Readme
    ..SharedDirectoryCD_1
    ..SharedDirectoryCD_2
    ..SharedDirectoryCD_3
    ..SharedDirectorySSP_FAMILY
    ..SharedDirectorySSP_G110_G120
    ..SharedDirectorySSP_HELP
    ..SharedDirectorySSP_SIMOTION_INTEGRATED
    ..SharedDirectorySSP_SINUMERIK_INTEGRATED
    ..SharedDirectoryUnsupported Tools
  4. Start the STARTER setup program by calling it from /CD_1/SETUP.EXE.

The readme file contains important notes on how to use the tool.

SINAMICS MICROMASTER STARTER V4.3 SP2 (previous version)

This contains version V4.3 SP2 of the STARTER commissioning tool for the SINAMICS, SIMATIC ET200 FC and MICROMASTER 4 drive systems. The download also contains the additive SINAMICS Support Packages in the 'Vol_2a_STARTER_V43_SP2_ SSPs_G110_G120.zip' and 'Vol_2b_STARTER_V43_SP2_ SSPs_Family_Integrated' files:

  • SSP SINAMICS V4.6
  • SSP SINAMICS G120 V4.6
  • SSP SINAMICS MV V4.6

These SSPs are automatically installed by the STARTER setup when the checkboxes are activated in the selection screen form.

SINAMICS MICROMASTER STARTER can be used free of charge without entering a license key. However, for legal licensing reasons, you should be in possession of a STARTER license certificate (any version). If this is not the case, you can also order the current STARTER version including license certificate on a DVD. Order number: 6SL3072-0AA00-0AG0.

STARTER V4.3 SP2 supports German, English, French, Spanish and Italian.

The following drive systems are supported
(recently included versions compared to the previous STARTER V4.3.2 are marked in bold):

  • MICROMASTER 4th Generation
  • SINAMICS DCM with Firmware V1.1, V1.2, V1.3
  • SIMATIC ET200S FC with Firmware V1.0.x, V3.0.x
  • SIMATIC ET200pro FC with Firmware V3.0.x
  • SINAMICS G110 with Firmware V1.0.x, V1.1.x
  • SINAMICS G110D with Firmware V3.3.x, V3.4.x
  • SINAMICS G120 with Firmware V2.0.x, V2.1.x, V3.0.x, V3.1.x, V3.2.x, V4.2, V4.3.0, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G120C with Firmware V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G120D with Firmware V3.0.x, V3.1.x, V3.2.x, V4.5 and (with SSP) V4.6
  • SINAMICS G120P with Firmware V4.2, V4.3.0, V4.3.2, V4.4, V4.5
  • SINAMICS G120P BT with Firmware V4.4.1
  • SINAMICS G130 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS G130 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS G150 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS G150 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS GM150 with Firmware V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS GM150 with Firmware V4.3.1, V4.4.2, V4.5 (--> SINAMICS MV)
  • SINAMICS GL150 with Firmware V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS GL150 with Firmware V4.3.1, V4.4.2, V4.5 (--> SINAMICS MV)
  • SINAMICS S110 with Firmware V4.1, V4.3.1, V4.3.2 and (with SSP) V4.4
  • SINAMICS S120 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS S120 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS S150 with Firmware V2.1.x, V2.2.x, V2.3.x, V2.4.x, V2.5.1, V2.6.1 and V2.6.2
  • SINAMICS S150 with Firmware V4.3.1, V4.3.2, V4.4, V4.5 and (with SSP) V4.6
  • SINAMICS SL150 with Firmware V4.3.1, V4.4.2, V4.5 (--> SINAMICS MV)
  • SINAMICS SM120 with Firmware V4.4.2
  • SINAMICS SM150i with Firmware V2.4.x, V2.5.1, V2.6.2, V4.5
  • SINAMICS MV with Firmware (with SSP) V4.5 and (with SSP) V4.6

Further details on the supported drive systems can be found in the following Excel overview.

Installed_Devices_STARTER_DVD_43020000.xls ( 105 KB )

Optional NEW
In order to save download time and data volume, STARTER version V4.3 SP3 can also be downloaded and installed WITHOUT online help. If you want to do without the online helps, select the 'Minimized' download variant.

Installation/download variant

Complete,
i.e. download file incl. online help

Minimized,
i.e. download file WITHOUT online help

Vol_1_STARTER_V43_SP2_Program.zip

YES

YES

Vol_2a_STARTER_V43_SP2_SSPs_G110_G120.zip

YES

YES

Vol_2b_STARTER_V43_SP2_SSPs_Family_Integrated.zip

YES

NO

Vol_3_STARTER_V43_SP2_Helps.zipYESNO

Installation procedure:

  1. Download the two or three attached ZIP files (depending on the selected download variant)
  2. Unpack the ZIP files into a shared target directory on the hard disk. Please ensure that no spaces are contained in the entire path name of this target directory.
  3. After unpacking, the shared directory must appear as follows:
    ..SharedDirectory01_Readme
    ..SharedDirectoryCD_1
    ..SharedDirectoryCD_2
    ..SharedDirectoryCD_3
    ..SharedDirectorySSP_INT_CD1
    ..SharedDirectorySSP_CD1
    ..SharedDirectoryUnsupported Tools
  4. Start the STARTER setup program by calling it from /CD_1/SETUP.EXE

The Readme file contains important notes on how to use the tool. Windows cursor pack.

Siemens Starter 4.5 Download

SSP, SINAMICS V4.6

Here, as individual download, you will find the SINAMICS Support Package (SSP) SINAMICS V4.6 that matches STARTER >= V4.3.1.x or SCOUT V4.3.1 HF12.

With this SINAMICS Support Package, SINAMICS drives belonging to the SINAMICS S120, G130, S150, G150 series with firmware release V4.6 can be configured and commissioned using STARTER V4.3.1.x or SCOUT V4.3.1 HF12.

Procedure for installing SSP:

  1. Download the attached ZIP file
  2. Unzip the ZIP file to a shared target directory on your hard disk
    Please ensure that there are absolutely no spaces in the complete path names of this target directory.
  3. After unpacking, the shared directory must appear as follows:
    ..01_Readme
    ..CD_1
  4. Start the SSP setup program by calling it from /CD_1/SETUP.EXE.

The readme file contains important notes on how to use the tool.

After installing SSP from STARTER V4.3.1.x or SCOUT V4.3.1 HF12, the following drive systems are also supported

  • SINAMICS V4.6

Note on online help for function release V4.6:
To access the online help for function release V4.6, download package Vol_3_STARTER_V43_SP3_HELPS.zip and run the corresponding setup.

  1. After unpacking, the shared directory must appear as follows:
    ..CD_1
    ..CD_2
    ..SSP_HELP..
  2. Start the SSP setup program by calling it from /SSP_HELP/OPT/SSP_SINAMICS_HELP_V4_6/CD_1/setup.exe.

More detailed information about STARTER V4.3.1.x is available under the article ID: 61585426

SSP, SINAMICS G120 CU250S VECTOR V4.6

Here, as individual download, you will find the SINAMICS Support Package (SSP) G120 CU250S-2 VECTOR V4.6 that matches the STARTER >= V4.3.2.x.

With this SINAMICS Support Package, you can configure and commission SINAMICS G120 CU250S-2 Vector with Firmware Version V4.6 with the STARTER >= V4.3.2.x.

Procedure for installing SSP:

  1. Download the attached ZIP file
  2. Unzip the ZIP file to a shared target directory on your hard disk
    Please ensure that there are absolutely no spaces in the complete path names of this target directory.
  3. After unpacking, the shared directory must appear as follows:
    ..01_Readme
    ..CD_1
  4. Start the SSP setup program by calling it from /CD_1/SETUP.EXE.

The readme file contains important notes on how to use the tool.

After installing SSP from STARTER V4.3.2.x, the following drive systems are also supported

  • SINAMICS G120 CU250S-2 VECTOR V4.6

More detailed information regarding the STARTER V4.3.2.x is provided in 64374921.

SSP, SINAMICS DCM V1.4

Here, as individual download, you will find the SINAMICS Support Package (SSP) SINAMICS DCM V1.4 which is suitable for the STARTER >= V4.3.2.x.

With this SINAMICS Support Package, you can configure and commission SINAMICS DCM with Firmware Version V1.4 with the STARTER >= V4.3.2.x.

Procedure for installing SSP:

  1. Download the attached ZIP file
  2. Unzip the ZIP file to a shared target directory on your hard disk
    Please ensure that there are absolutely no spaces in the complete path names of this target directory.
  3. After unpacking, the shared directory must appear as follows:
    ..01_Readme
    ..CD_1
  4. Start the SSP setup program by calling it from /CD_1/SETUP.EXE.

The readme file contains important notes on how to use the tool.

After installing SSP from STARTER >= V4.3.2.x, the following drive systems are also supported

  • SINAMICS DCM V1.4

More detailed information regarding the STARTER V4.3.2.x is provided in 64374921.

SSP, SINAMICS G120 V4.6

Here, as individual download, you will find the SINAMICS Support Package (SSP) SINAMICS G120 V4.6 which is suitable for the STARTER >= V4.3.1.x resp. SCOUT V4.3.1 HF12.

With this SINAMICS Support Package, you can configure and commission SINAMICS G120 drives with Firmware Version V4.6 with the STARTER V4.3.1.x or SCOUT V4.3.1 HF12.

Procedure for installing SSP:

  1. Download the attached ZIP file
  2. Unzip the ZIP file to a shared target directory on your hard disk
    Please ensure that there are absolutely no spaces in the complete path names of this target directory.
  3. After unpacking, the shared directory must appear as follows:
    ..01_Readme
    ..CD_1
  4. Start the SSP setup program by calling it from /CD_1/SETUP.EXE.

Siemens Starter Software 4.5 Download

The readme file contains important notes on how to use the tool.

After installing SSP from STARTER V4.3.1.x or SCOUT V4.3.1 HF12, the following drive systems are also supported

  • SINAMICS G120 V4.6

Note on the online hep for function release V4.6:
The online help is contained in SSP and automatically installed.

More detailed information regarding the STARTER V4.3.1.x is provided in 61585426.

SSP, SINAMICS MV V4.6

Siemens Starter 4.5 Download Offline

The SINAMICS Support Package (SSP) SINAMICS MV V4.6 suitable for STARTER >= V4.3.1.x or for SCOUT V4.3.1 HF12 can be downloaded here.

The existing SINAMICS Support Package allows you to configure and commission SINAMICS drives of the SINAMICS MV with firmware version V4.6 with STARTER V4.3.1.x or SCOUT V4.3.1 HF12.

How to install the SSPs:

  1. Download the attached ZIP file
  2. Unzip the ZIP file to a shared target directory on your hard disk
    Please ensure that there are absolutely no spaces in the complete path names of this target directory.
  3. After unpacking, the shared directory must appear as follows:
    ..01_Readme
    ..CD_1
  4. Start the SSP setup program by calling it from /CD_1/SETUP.EXE.

The readme file contains important notes on how to use the tool.

After installing SSP from STARTER V4.3.1.x or SCOUT V4.3.1 HF12, the following drive systems are also supported

  • SINAMICS MV V4.6

Note on the online help for function release V4.6:
To access the online help for function release V4.6, download package Vol_3_STARTER_V43_SP3_HELPS.zip and run the corresponding setup.

  1. After unpacking, the shared directory must appear as follows:
    ..CD_1
    ..CD_2
    ..SSP_HELP..
  2. Start the SSP setup program by calling it from /SSP_HELP/OPT/SSP_SINAMICS_HELP_V4_6/CD_1/setup.exe.

More detailed information about STARTER V4.3.1.x itself is available under the article ID: 61585426

Download note

Due to security settings, a download - as marked in the screenshot - may be classified as a security risk.
To avoid problems after the installation, zip files must be classified as harmless after downloading by clicking with right mouse button > Properties > 'Unblock' button