20.12.2020»»воскресенье

Guardian Gas Furnace Manual

20.12.2020
Loading.
  • View and Download Guardian Technologies GERM GUARDIAN EV9102 instruction manual online.
  • Orion Engineered Carbons S.A. Announces Exercise And Closing Of Greenshoe Option Stanley & Co. LLC, 1585 Broadway, New York, New York 10036.
  • Upflow natural gas furnaces - 92% hvac service parts supersedes: nothing 035-20372-001 rev. A (0504) 1 of 8 figure 1: upflow natural gas furnaces (92%) fig item description gf9s060b12up11g gf9s080b12up11g gf9s080c16up11g.
  • York furnaces offer high energy efficiency and reliable comfort for homes across the U.S. As one of the nation’s leading furnace manufacturers, York delivers the warmth your family needs throughout the cold season while conserving energy to keep your utility bills low.

USE & CARE INSTRUCTIONS

View and Download Johnson Controls GG9S.MP installation manual online. RESIDENTIAL GAS FURNACE 95.5% AFUE Single Stage Multi-position. GG9S.MP furnace pdf manual download. Also for: Tg9s.mp, Tg9s040a08mp11, Gg9s040a08mp11, Tg9s060a10mp11, Gg9s060a10mp11, Tg9s060b12mp11, Gg9s060b12mp11. HIGH-EFFICIENCY UPFLOW FURNACE INSTALLER'S INFORMATION MANUAL HIGH-EFFICIENCY UPFLOW FURNACE INSTALLER'S INFORMATION ATTENTION, INSTALLER.

Model No. EV9102

5-Year Limited Warranty www.germguardian.com

1.866.603.5900

Germ Guardian®

UV-C Room

Air Sanitizer

REPLACEMENT PART INFORMATION

Model No: EV9LBL Filter + Bulb

Call Customer Service 1.866.603.5900

Replace every 8-10 months depending on use.

ONLINE WARRANTY REGISTRATION

©2009 Guardian Technologies LLC

w w w . g e r m g u a r d i a n . c o m

English E - 1

French F - 1

Spanish S - 1

Date Purchased

month ________

E-1

year _________

PLEASE READ AND SAVE ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

DANGER: Electrical Shock

Use this product only as described in this manual.

Operate this product on 120V AC, 60HZ only.

IMPORTANT SAFETY INSTRUCTIONS - This portable luminaire has a polarized plug (one blade is wider thatn the other) as a feature to reduce the risk of electric shock. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse plug. If it still does not fit, contact a qualified electrician. Never use an extension cord unless plug can be fully inserted. Do not alter the plug.

Do not operate this product with a damaged cord or if there is any physical damage to the unit.

WARNING: the cords, wires and/or cables supplied with this product contain chemicals, including lead or lead compounds, known to the state of california to cause cancer and birth defects or other reproductive harm; Wash hands after using.

Inch by inch download mac. This product is for indoor use only.

Do not operate this product in any area where there is a risk of the unit falling into or being exposed to water.

WARNING: Electrical Shock

TO reduce the risk of injury

Always unplug the unit before servicing.

Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the device.

Do not carry this unit by the cord or use the cord as a handle.

Do not handle the unit or plug with wet hands.

Keep the cord away from heated surfaces.

Do not unplug the unit by pulling on the cord. Grasp the plug itself, when unplugging from an outlet.

Do not put any objects into the openings or block the airflow to the unit.

Do not operate without cover in place.

Do not defeat interlock switch.

Do not operate with an extension cord.

Opening windows or doors while operating this device may affect performance.

This device should not be used in the presence of oxygen or any flammable liquid or gases.

CAUTION

ULtraviolet-c light is emitted from the bulb when the unit is electrified. sever eye injury or skin irritation could result. do not operate the unit if the enclosure is damaged. do not expose skin or eyes to within 3-inches of the air intake or output for a period of 3 hours or more. skin or eye irritation could result.

E-2

How It Works

The Germ Guardian's powerful fan moves air through the center chamber where germs are bombarded with ultraviolet-C light. The highly reflective chamber maximizes the germ-killing power of the UV-C light and the microorganisms passing through it

Guardian Gas Furnace Manual

are destroyed. Sanitized air then flows back into the room.

NOTE: It is recommended to run the EV9102 continuously. Opening doors and/or windows may affect the performance of the device.

E-3

UV-C Light Bulb & Filter

Ultraviolet light technology, the same technology used in hospitals and commercial settings for sanitizing, is capable of eradicating mircoorganisms, mold spores and viral contaminants from the air.

It is recommended that you leave the Germ Guardian UV-C Air Sanitizer running continuously. A replaceable 9-watt UV-C light bulb is guaranteed to last 8,000 hours - almost a full year of continuous use. A filter that helps reduce odors is also in the product and should be replaced once a year. Over time, with use, the 9-watt UV-C bulb will lose some intensity (about 15% at 9,000 hours), therefore it is suggested that the light bulb be replaced once every year. You will know when to change the 9-watt light bulb when it continuously flickers or changes color. The replacement bulb and filter come in one package.

To reorder bulb & filter pack EV9LB or EV9LBL, please call Customer Service 1.866.603.5900 or go to www.germguardian.com. Nikon capture nx2 v2.3 full serial key.

WARNING: Electrical Shock

Furnace

Guardian Gas Furnace Owners Manual

under no circumstances should you clean the bulb, bulb holder or cylinder with water or wet solutions. This could cause electrical shock.

Use of the Germ Guardian Unit

When the Germ Guardian is turned on you will see two rings of blue light that let you know it is working. The Germ Guardian UV-C Room Air Sanitizer can process 1,380 cubic feet of air per hour and is effective in almost any size room. Depending on dust conditions and build-up, you may need to occasionally clean the bulb and cylinder with a soft, dry cloth. This product is safe for use around children and pets, and is cool to the touch.

Directions for Use

1.Plug unit into a 120V AC electrical outlet.

2.Switch the power button to the ON position.

A small red light should light up on the switch.

3. Use the knob next to the power switch to adjust the fan speed. Turn the knob clockwise for increased air flow.

4.For best results continuous operation

is recommended.

Note: the germ guardian unit contains no serviceable parts except its uv-c bulb and filter. the bulb and filter may be removed for replacement.

Important Safety Instructions

WARNING: Electrical Shock

Always unplug the germ guardian unit from electrical outlet when servicing.

Replacing and Cleaning the UV-C Bulb & Filter

1.Turn off the unit and unplug it from

the electrical outlet.

2. Using a small phillips head screwdriver, loosen and remove the phillips screw located at the top of the unit, directly above the power cord.

3.Remove the top cap by lifting its side near the screw hole, then gently push the cap in the opposite direction.

4. As the cap loosens, you may lift it off.

Replacing and Cleaning the UV-C Bulb & Filter

York Guardian Gas Furnace Manual

5.Remove the (2) phillips screws located on each side of the bulb holder and remove the filter.

6.Lift bulb holder from cylinder. Do not touch bulb. If cleaning, insert soft, dry cloth into cylinder and remove. Repeat if necessary. Do not touch bulb with bare hands. Fingerprints may result in reduced performance unless they are removed with an

alcohol pad. Use a soft cloth as a barrier against contact.

7. If NOT replacing the bulb for the first time jump to step 8. If replacing the bulb for the first time, flip bulb holder over so light bulb faces up. There will be a spring located between the bulb cylinders. Squeeze spring tightly towards bulb and pull out of holder and through bulb. Discard spring. Spring is used for shipping purposes only and does not need to be replaced.

8.Grasp the metal collar on the bulb and pull firmly until bulb unplugs from the bulb holder. When inserting new bulb, make sure the bulb snaps and is locked firmly in place. Reassemble by reversing steps 1-8.

E-6

TROUBLESHOOTING GUIDE

PROBLEM

SOLUTION

Unit doesn't operate.

Check that unit is plugged in. Call

Customer Service at 1.866.603.5900.

Light flickers.

Bulb burnt out. See Replacing

UV-C Bulb section of manual.

Fan runs but no light.

Bulb burnt out. See Replacing

UV-C Bulb section of manual.

Low air flow.

Check fan setting knob, turn clockwise

to high. Replace filter. See Replacing

UV-C Bulb and Filter section of manual.

E-7

warning:

ultraviolet-c light is emitted from the bulb when the unit is electrified, severe eye injury or irritation could result, unplug the unit when servicing the bulb to avoid exposure of eyes and skin to the ultraviolet-c light.

Discard the old bulb by following the recommended disposal procedure for a used fluorescent bulb.

The bulb should only be used in the Germ Guardian unit and all instructions for use must be followed.

WARNING:

misapplying or misusing the uv-c bulb could cause injury to the eyes or skin. never use the bulb without installing it in the unit as instructed. never operate the unit without the top cap in place.

This product can be serviced or maintained only by changing the UV-C bulb. The bulb contains no serviceable parts. All parts, except the UV-C bulb, are warranted for five full years from date of purchase. See the Limited Warranty. Use of any bulb other than the appropriate Germ Guardian bulb will void the warranty.

You may purchase bulbs directly from Guardian Technologies LLC, or we can provide the names of retailers who stock our products.

Air Filtering Appliance 14DH

The health aspects associated with this product and its ability to aid in the disinfection of environmental air have not been investigated by UL.

The purchase of a Germ Guardian unit does not prevent illness. The Germ Guardian unit is designed to kill over 99% of bacteria.

Germ Guardian is a registered trademark of Guardian Technologies LLC.

Limited warranty

To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of original purchase. Save your original sales receipt to validate start of warranty period.

If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. The complete machine must be delivered pre-paid to any authorized Guardian Technologies LLC warranty service center. Please include complete information on the problem, date of purchase, copy of original sales receipt and your name, address and telephone number. If you are not near a warranty center, call the factory for assistance in the US and Canada at 1.866.603.5900. Use only genuine Guardian Technologies replacement parts.

The warranty does not include unusual wear, damage resulting from accident, or unreasonable use of the product. This warranty does not cover bulbs. This warranty does not cover unauthorized repairs. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.).

We consider the registration process important to ensuring superior service to our customers, however submitting the warranty card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above. If you have any questions or comments about our product call toll free at 1.866.603.5900 or send comments to:

ATTN: Customer Service Guardian Technologies LLC 7700 St Clair Avenue Mentor, Ohio 44060

important

The UV-C bulb is specifically excluded from this warranty. Use only a Guardian Technologies replacement bulb. See the section under the heading 'Replacing and Cleaning the UV-C Bulb and Filter.'

The Germ Guardian contains no serviceable parts. Due to the unique technology of the Germ Guardian, all repairs must be performed by Guardian Technologies authorized service centers. Any unauthorized repair or tampering with the Germ Guardian VOIDS this warranty. /video-grabber-vc-211a-driver-download.html. This warranty does not cover misuse or abuse.

mercury notice

This device contains mercury in the sealed ultraviolet bulbs. Do not place your used bulb(s) in the trash. Dispose of properly.

broken bulb clean up

Do not use a household vacuum. Sweep debris (phosphor/glass) into a plastic bag and dispose of properly. It is recommended that the UV-C bulbs are recycled or taken to a household-hazardous- waste collection center. Call your county recycling coordinator to find the recycling center nearest you.